Roof Disconnectors

The roof disconnecting switches, change-over switches and disconnecting-earthing switches are designed for no-load disconnecting, reconnecting and earthing of electric circuits of the traction vehicle. The switches can be controlled with pneumatic or electric drive that can be equipped by emergency manual control or it could be controlled manually only.  The switches are intended for installation to the roof hole or on the roof. The disconnecting path is always visible.

Compliant with IEC 60077-1, 2, EN50124-1 and EN 50163, EN45545-2, EN50388, NFPA130 (indoor applications).

Benefits for you

  • Modular solution easily adaptable to different configurations
  • Vertical or horizontal design of the disconnecting path
  • 50% space- and weight-saving solution (vertical solution in comparison to horizontal solution)
  • 5 years maintenance-free
  • Short circuit withstands capability up to 100 kA/ 60 ms
  • Robust design
  • Service proven solution (more than 30 years)
  • Options:
    • Surge arrestor
    • Lock system
    • Manual control
    • Revolving head for rigid HV connection
    • Contact protection against ice layer

Main Parameters

Descriptions

Parameters

Temperature range

-50° C ÷ + 70°C (or according to request)

Rated voltage

Up to 25 kV AC

Nominal current

Up to 4,000 A

Control voltage

(24, 72) 110 V DC (or according to request)

Overvoltage degree

OV3/OV4 EN 50124-1

Pollution degree

PD4 EN 50124-1

Product Variants
Roof Disconnectors

Disconnecting-Earthing Switches

Disconnecting – earthing switches protect by earthing function 1,5 kV and 3 kV circuits during operations under AC overhead line.

  • For main line and high speed
  • Indoor/ outdoor installation (on the roof, in the roof hole)
  • IP65 between HV and LV part
  • Controlled manually, with electric drive or pneumatic drive
  • Vertical / horizontal solution
  • Roof switches for pure DC operation available
Parameters
Descriptions

Parameters

Temperature range

-50° C ÷ + 70°C (or according to request)

Rated voltage

Up to 25 kV AC

Nominal current

Up to 4,000 A

Control voltage

(24, 72) 110 V DC or according to request

Overvoltage category

OV3/OV4 EN 50124-1

Pollution degree

PD4 EN 50124-1

Products Gallery
Roof Disconnectors

Disconnecting Switches

  • For main line and high speed
  • Indoor/ outdoor installation (on the roof, in the roof hole)
  • Roof line disconnecting
  • IP65 between HV and LV part
  • Controlled manually, with electric drive or pneumatic drive
  • Horizontal solution
  • Roof switches for pure DC operation available
Parameters
Descriptions

Parameters

Temperature range

-50° C ÷ + 70°C (or according to request)

Rated voltage

Up to 25 kV AC

Nominal current

Up to 4,000 A

Control voltage

(24, 72) 110 V DC (or according to request)

Overvoltage degree

OV3/OV4 EN 50124-1 

Pollution degree

PD4 EN 50124-1

Products Gallery
Roof Disconnectors

Change-Over Switches

  • For main line and high speed
  • Indoor/ outdoor installation (on the roof, in the roof hole)
  • Switching between traction systems
  • IP65 between HV and LV part
  • Controlled manually, with electric drive or pneumatic drive
  • Horizontal solution
  • Roof switches for pure DC operation available
Parameters
Descriptions

Parameters

Temperature range

-50° C ÷ + 70°C (or according to request)

Rated voltage

Up to 25 kV AC

Nominal current

Up to 4,000 A

Control voltage

(24, 72) 110 V DC (or according to request)

Overvoltage degree

OV3/OV4 EN 50124-1

Pollution degree

PD4 EN 50124-1

Products Gallery
Roof Disconnectors

Earthing Switches

  • For main line and high speed
  • Indoor/ outdoor Installation (on the roof, in the roof hole)
  • Roof line earthing
  • IP65 between HV and LV part
  • Controlled manually, with electric drive or pneumatic drive
  • Horizontal / vertical solution
  • Roof switches for pure DC operation available

 

Parameters
Descriptions

Parameters

Temperature range

-50° C ÷ + 70°C (or according to request)

Rated voltage

Up to 25 kV AC

Control voltage

(24, 72) 110 V DC (or according to request)

Overvoltage degree

OV3/OV4 EN 50124-1

Pollution degree

PD4 EN 50124-1

Products Gallery
Inquiry Form

Can We Help You?

Vlasta Hrůzová

Product Specialist

Write to our specialist.

Vlasta will be happy to help you and answer your questions.

Fields with * are required.
By clicking submit button you agree to the Privacy Policy.

What you're looking for?